Zhao Shuquan.Fission track analysis method of urine plutonium and estimation of plutonium-239 internal dose to Marshallese[J].Chinese Journal of Radiological Medicine and Protection,1995,15(4):237-242
Fission track analysis method of urine plutonium and estimation of plutonium-239 internal dose to Marshallese
Received:November 17, 1994  Revised:May 04, 1995
DOI:
KeyWords:Marshall Islands  Bravo fallout  plutonium  urinalysis  fission track analysis
FundProject:
Author NameAffiliation
Zhao Shuquan Institute of Radiation Medicine,Shanghai Medical University, Shanghai, 200032 
孙连陞 美国纽约布鲁克海文国家实验室 
Hits: 3559
Download times: 1763
Abstract::
      Bravo detonated at Bikini Atoll on the morning of March 1, 1954,unexpectedly released a large amount of radioactive fallout on the areas.Impact studies on the radiological health and safety of the residents living in the contaminated environments are still undergoing. For plutonium dose assessment.researchers at Brookhaven National Laboratory established a fission track analysis (FTA) method for low-level 239Pu measurement. Furthermore, a new shipboard protocol was developed for collecting 24-h radiologically clean urine sampies. The purposes of this paper are to update information on the FTA processes and to present a set of results on the 239Pu measurements in the Marshallese populations (Rongelap and Utirik) between 1981-1991. The detection sensitivity of FTA method(99% confidence level)in these samples was 2-3 μBq which is equivalent to 0.2-0.3 mSv effective dose equivalent (EDE) to age 70 for the Marshallese.The latest 1991 FTA data indicate average EDE of 0.62mSv and 1.6 mSv for the people of Rongelap and Utirik, respectively, which both are the highest values since 1988.
HTML  View Full Text  View/Add Comment  Download reader
Close

Copyright©    Editorial Office of Chinese Journal of Radiological Medicine and Protection    

Beijing ICP No. 05020547 -2

Address: 2 Xinkang Street, Dewai, Beijing 100088, China

Telephone:010-62389620; Email:cjrmp@cjrmp.sina.net

Technical Support:Beijing E-tiller CO.,LTD.

Visitors:12030433  On-line:0

v
Scan QR Code
&et=E83B42E7B81B9BB3A3F15E52DB03407C8F6BC94BB75EAFF3F7E9DEAEDB46F94FCD118EDA809C68A611D713B865ED58711E92C19F4B556C6358198143DDDA7C9F0E88A089858F41C237430206F234332CE5AAD4444B199AA55BA66EB46590A35AC81A35EBE765B86E8687ADC82B4F710A&pcid=A9DB1C13C87CE289EA38239A9433C9DC&cid=D4D466D60FDC1A5A&jid=5E4353813E091AB841B02B880782B82C&yid=BBCD5003575B2B5F&aid=57387B4018C200E7C17ABADA25DE2A59&vid=&iid=E158A972A605785F&sid=FE4C96E058BB2280&eid=0C191C6ECF79047F&fileno=19950406&flag=1&is_more=0"> var my_pcid="A9DB1C13C87CE289EA38239A9433C9DC"; var my_cid="D4D466D60FDC1A5A"; var my_jid="5E4353813E091AB841B02B880782B82C"; var my_yid="BBCD5003575B2B5F"; var my_aid="57387B4018C200E7C17ABADA25DE2A59";