朱海生,王仁生,严浩林,黄俊华,陈明东,伍纶庆,阙丽琳,梁雷锋.SPECT/CT同机融合显像检测鼻咽癌侵犯颅底骨的临床价值[J].中华放射医学与防护杂志,2017,37(2):132-137
SPECT/CT同机融合显像检测鼻咽癌侵犯颅底骨的临床价值
Clinical value of 99Tcm-MDP SPECT/CT in diagnosing skull base bone involvement of nasopharyngeal carcinoma
投稿时间:2016-09-06  
DOI:10.3760/cma.j.issn.0254-5098.2017.02.009
中文关键词:  鼻咽肿瘤  颅骨  体层摄影术  发射型计算机  单光子  99Tcm-亚甲基二膦酸盐
英文关键词:Nasopharyngeal neoplasms  Skull  Tomography  Emission-computed  Single-photon  99Tcm-methylene diphosphonate
基金项目:
作者单位E-mail
朱海生 537000 玉林, 广西玉林市第一人民医院 广西医科大学第六附属医院肿瘤科  
王仁生 530021 南宁, 广西医科大学第一附属医院放疗科 ylzhuhaisheng@163.com 
严浩林 537000 玉林, 广西玉林市第一人民医院 广西医科大学第六附属医院肿瘤科  
黄俊华 537000 玉林, 广西玉林市第一人民医院 广西医科大学第六附属医院核医学科  
陈明东 537000 玉林, 广西玉林市第一人民医院 广西医科大学第六附属医院放射科  
伍纶庆 537000 玉林, 广西玉林市第一人民医院 广西医科大学第六附属医院肿瘤科  
阙丽琳 537000 玉林, 广西玉林市第一人民医院 广西医科大学第六附属医院肿瘤科  
梁雷锋 537000 玉林, 广西玉林市第一人民医院 广西医科大学第六附属医院肿瘤科  
摘要点击次数: 2640
全文下载次数: 2268
中文摘要:
      目的 探讨99Tcm-亚甲基二膦酸盐(MDP)SPECT结合定位CT对鼻咽癌(NPC)颅底骨侵犯(SBBI)检测能力及临床价值。方法 对165例鼻咽癌初治患者于放疗前同期进行99Tcm-MDP SPECT结合定位CT鼻咽颅底断层骨显像和MRI检查。于SPECT/CT图像矢状面,颅底放射性浓聚程度最高(L)层面与高位颈椎体(C1~C3,S)处勾画相同大小的感兴趣区(ROI),计算其放射性摄取比值,L/S>1提示SBBI。以MRI结果为标准,采用双盲法对两者检测结果进行比较。根据肿瘤的不同侵犯途径,进一步把颅底骨分斜坡、岩尖、蝶骨体、蝶窦底和翼突、翼板等区域进行统计分析。结果 SPECT/CT检测SBBI总体灵敏度、特异性、准确度、阳性预测值、阴性预测值、к值分别为96.74%(89/92)、72.60%(53/73)、86.06%(142/165)、81.65%(89/109)、94.64%(53/56)、0.711,ROC曲线下面积0.847,差异有统计学意义(Z=12.436,P<0.01);斜坡、岩尖区域的阳性预测值(91.67%)明显高于蝶骨体、蝶窦底区域和翼突、翼板区域的阳性预测值(30.00%、14.29%)。结论 99Tcm-MDP SPECT/CT能有效地检测鼻咽癌SBBI,尤其在斜坡、岩尖区域,与MRI检测结果高度一致。
英文摘要:
      Objective To evaluate the diagnostic value of 99Tcm-methylene diphosphonate(MDP)SPECT/CT in skull base bone involvement (SBBI) of nasopharyngeal carcinoma (NPC).Methods Whole-body and skull-base tomography 99Tcm-MDP SPECT/CT and MRI were applied in 165 untreated NPC patients. The radioactive counts within a region of interest (ROI) of suspected SBBI (L) were delineated from the sagittal plane of SPECT images. The radioactive counts within a same size ROI of upper cervical vertebra C1 to C3(S) were also analyzed. The ratio of L and S (L/S) was calculated. L/S > 1 indicates SBBI.MRI data was used as a standard control. The results were double-blind compared and evaluated.In addition, SBBI was further analyzed in different regions,includingthe clivus and petrous apex region of the skull base, the base of sphenoid bone and sphenoid sinus region, the Pterygoid process and lamina lateralis and lamina medialis region. Results The sensitivity, specificity, accuracy, positive predictive value, negative predictive value and κ value for SBBI detection by SPECT/CT were 96.74%(89/92), 72.60%(53/73), 86.06%(142/165), 81.65%(89/109), 94.64%(53/56) and 0.711, respectively. The area under the ROC (receiver operating characteristic) curve (AUC) was 0.847, which showed statistically significant difference (Z=12.436, P<0.01). In the SBBI evaluation by SPECT/CT for different regions, the positive predictive value of SPECT/CT for SBBI detection in the clivus and petrous apex region of the skull base was significantly higher than that in the base of sphenoid bone, sphenoid sinus region, the pterygoid process, lamina lateralis and lamina medialis region (91.67% vs. 30.00%,14.29%) Conclusions 99Tcm-MDP SPECT/ CT could be used for the detection of nasopharyngeal SBBI, especially in the clivus and petrous apex region of the skull base. The test results were highly consistent with the MRI findings.
HTML  查看全文  查看/发表评论  下载PDF阅读器
关闭