戴宏,刘玉龙,王优优,等.南京“5.7” 192Ir放射事故患者三种生物剂量估算指标的衰变规律探讨[J].中华放射医学与防护杂志,2016,36(5):355-358.Dai Hong,Liu Yulong,Wang Youyou,et al.Dynamic analysis on three indexes of biological dose estimation of the victim exposed to 192Ir radiation source at “5.7” accident in Nanjing[J].Chin J Radiol Med Prot,2016,36(5):355-358
南京“5.7” 192Ir放射事故患者三种生物剂量估算指标的衰变规律探讨
Dynamic analysis on three indexes of biological dose estimation of the victim exposed to 192Ir radiation source at “5.7” accident in Nanjing
投稿时间:2016-02-05  
DOI:10.3760/cma.j.issn.0254-5098.2016.05.009
中文关键词:  192Ir  生物剂量估算  染色体畸变  微核  核质桥
英文关键词:192Ir  Biological dose estimation  Chromosomal aberrations  Micronuclei  Nucleoplasmic bridges
基金项目:江苏省临床医学科技专项(BL2014040);江苏省卫生计生委2014-2015年度预防医学科研项目(Y2015024);江苏省研究生培养创新工程项目(SJLX15-0580)
作者单位E-mail
戴宏 215004 苏州, 苏州大学附属第二医院应急中心  
刘玉龙 215004 苏州, 苏州大学附属第二医院应急中心 yulongliu2002@126.com 
王优优 215004 苏州, 苏州大学附属第二医院应急中心  
冯骏超 215004 苏州, 苏州大学附属第二医院应急中心  
赵骅 100088 北京, 中国疾病预防控制中心辐射防护与核安全医学所 辐射防护与核应急中国疾病预防控制中心重点实验室  
刘青杰 100088 北京, 中国疾病预防控制中心辐射防护与核安全医学所 辐射防护与核应急中国疾病预防控制中心重点实验室  
郭凯琳 215004 苏州, 苏州大学附属第二医院应急中心  
摘要点击次数: 4525
全文下载次数: 3025
中文摘要:
      目的 观察南京"5.7" 192Ir放射事故患者受照后不同采血时间对生物剂量估算的影响,探讨3种生物剂量估算指标在体内的自然衰减规律。方法 事故后5、40和280 d,采集患者的外周血,分别进行外周血淋巴细胞染色体"双着丝粒+环"("dic+r")畸变分析、胞质分裂阻滞微核(CBMN)分析、核质桥+融合+马蹄形+环(NPB +FHC)分析。观察受照后不同时间染色体"dic+r"畸变、微核、NPB +FHC衰变情况及对生物剂量估算结果的影响。结果 与事故后5 d的估算剂量相比,在40和280 d,染色体"dic+r"畸变分析估算的剂量分别下降34%和49%, CBMN的估算结果分别下降48%和79%,NPB +FHC的估算结果分别下降48%和75%。结论 本例事故患者受照后3种生物剂量估算指标在体内呈进行性下降,染色体"dic+r"/细胞的半衰期为40 d,3个指标在40 d时剂量估算结果与5 d时比较,相对偏差 > 20%。
英文摘要:
      Objective To explore the natural attenuation pattern of three biological dose estimation indexes in vivo by investigating the effect on biological dosimetry of peripheral blood sampling at different time points from the victim partially exposed to 192Ir radiation source at "5.7" accident in Nanjing.Methods Peripheral blood of the patient was collected on days 5, 40 and 280 after exposure, respectively. The yields of dicentrics plus rings chromosomes ("dic+r"), cytokinesis-block micronuclei (CBMN) and nucleoplasmic bridge+fusion+horse shoe+circular(NPB+FHC) were analyzed. The dynamic reduction and dose estimation were both observed using the biomarkers mentioned above after exposure. Results Compared to the estimates on days 5 after exposure, the dose values estimated on days 40 and 280 decreased by 34% and 49% for "dic+r" method, 48% and 79% for the CBMN assay, and 48% and 75% for NPN+FHC method, respectively. Conclusions Three biological dose estimation indexes show a progressive decrease in vivo, with the half-life of "dic+r"/cell being 40 days. The doses estimated using these three indexes on days 40 after exposure showed a relative deviation more than 20% compared with those on days 5 after exposure.
HTML  查看全文  查看/发表评论  下载PDF阅读器