赵艳芳,楚彩芳,张钦富,等.河南省CT检查所致受检者剂量调查与分析[J].中华放射医学与防护杂志,2020,40(3):227-232.Zhao Yanfang,Chu Caifang,Zhang Qinfu,et al.Investigation and analysis of CT doses to examined individuals in Henan province[J].Chin J Radiol Med Prot,2020,40(3):227-232
河南省CT检查所致受检者剂量调查与分析
Investigation and analysis of CT doses to examined individuals in Henan province
投稿时间:2019-04-16  
DOI:10.3760/cma.j.issn.0254-5098.2020.03.012
中文关键词:  CT  CT剂量指数  剂量长度乘积  有效剂量  诊断参考水平
英文关键词:CT  CT dose index  Dose length product  Effective dose  Diagnostic reference level
基金项目:2018年度河南省医学科技攻关计划联合共建项目(2018020572)
作者单位E-mail
赵艳芳 河南省职业病防治研究院放射卫生科, 郑州 450052  
楚彩芳 河南省职业病防治研究院放射卫生科, 郑州 450052  
张钦富 河南省职业病防治研究院放射卫生科, 郑州 450052 zhangqinfu66@163.com 
程晓军 河南省职业病防治研究院放射卫生科, 郑州 450052  
李永兴 河南省职业病防治研究院放射卫生科, 郑州 450052  
罗晓芳 河南省职业病防治研究院放射卫生科, 郑州 450052  
董柄臣 河南省职业病防治研究院放射卫生科, 郑州 450052  
武丽 河南省职业病防治研究院放射卫生科, 郑州 450052  
摘要点击次数: 3964
全文下载次数: 1639
中文摘要:
      目的 研究河南省CT检查所致儿童和成人受检者的剂量水平,探讨其影响因素,为制定我国和地区CT诊断参考(指导)水平提供基础资料。方法 采用分层配额抽样方法选取河南省7个地市31台CT共计1 113例受检者主要检查类型进行剂量调查,调查内容包括受检者和设备基本信息、扫描参数、相关剂量学信息等,通过剂量转换系数估算其所致典型有效剂量。结果 头部常规CT扫描中,0~1岁、>1~5岁、>5~10岁、>10~15岁组儿童CTDIw的75%分位值分别为32.2、37.2、43.0、46.7 mGy,DLP的75%分位值分别为478.0、572.0、715.6、743.9 mGy·cm,有效剂量分别为5.26、3.83、2.86、2.38 mSv;在胸部常规扫描中,0~1岁、>1~5岁、>5~10岁、>10~15岁组儿童CTDIw的75%分位值均为9.3 mGy,DLP的75%分位值分别为141.7、178.8、224.0、238.7 mGy·cm,有效剂量分别为5.53、4.64、4.03、3.10 mSv。CT检查所致成人受检者头部、胸部、腹部CTDIw的75%分位值分别为57.4、16.2、19.4 mGy,DLP的75%分位值分别为818.3、504.7和571.1 mGy·cm,有效剂量分别为1.72、7.07和8.57 mSv。结论 随着河南省CT设备的更新,检查技术的日益进步以及CT应用频度的快速增长,医疗机构应恰当选取CT各类检查的扫描参数,加强其影像质量及其所致剂量的优化匹配研究,完善CT诊断参考(指导)水平,尤其是对射线敏感的儿童应尽快建立诊断参考(指导)水平,推动CT检查医疗照射防护最优化。
英文摘要:
      Objective To study the level of doses which children and adults received from CT examinations in Henan province, and to explore the influencing factors, so as to provide basic data for the development of diagnostic reference (guidance) level for CT examination in China and related regions. Methods A total of 1 113 subjects, which have received examinations by 31 CT scanners separately in 7 cities of the province, were selected using stratified quota sampling method to carry out the dose survey, including basic information on subjects, equipment, scanning parameters, and dosimetry, etc. Typical effective dose was estimated by using dose conversion coefficient. Results In the conventional CT scanning of head. The 75% of CTDIw for children aged 0-1, >1-5, >5-10 and >10-15 years were 32.2, 37.2, 43.0 and 46.7 mGy; 75% of DLP were 478.0, 572.0,715.6 and 743.9 mGy·cm and effective doses were 5.26, 3.83,2.86 and 2.38 mSv, respectively. In the routine chest scanning, 75% of CTDIw for children aged 0-1, >1-5, >5-10 and >10-15 years were all 9.3 mGy. The 75% of DLP were 141.7, 178.8, 224.0 and 238.7 mGy·cm; and effective doses were 5.53, 4.64 4.03 and 3.10 mSv, respectively. 75% of CTDI\-w for head, chest and abdomen of the adult subjects from CT examinations were 57.4, 16.2 and 19.4 mGy, respectively. The 75% of DLP were 818.3, 504.7 and 571.1 mGy·cm, respectively, and effective doses were 1.72, 7.07 and 8.57 mSv, respectively. Conclusions As the update of CT equipment, increasing progress in examination technology and rapid increase in CT application frequency, medical institutions should choose the scanning parameters with respect to various types of CT scanner to optimize the image quality and the radiation doses. The diagnostic reference level for CT examination should be improved, especially for children.
HTML  查看全文  查看/发表评论  下载PDF阅读器
关闭