蒲进,夏春潮,赵飞,等.双源CT大螺距联合智能调制及迭代重建技术在主动脉夹层成像中的应用[J].中华放射医学与防护杂志,2019,39(1):6-10.Pu Jin,Xia Chunchao,Zhao Fei,et al.Application of dual-source CT combined with intelligent modulation and iterative reconstruction in aortic dissection imaging[J].Chin J Radiol Med Prot,2019,39(1):6-10
双源CT大螺距联合智能调制及迭代重建技术在主动脉夹层成像中的应用
Application of dual-source CT combined with intelligent modulation and iterative reconstruction in aortic dissection imaging
投稿时间:2018-01-24  
DOI:10.3760/cma.j.issn.0254-5098.2019.01.002
中文关键词:  急诊  主动脉  夹层  血管造影  计算机断层成像
英文关键词:Emergency  Aorta  Interlayer  Angiography  CT
基金项目:四川省科技厅重点研发项目(2017SZ0016)
作者单位E-mail
蒲进 四川大学华西医院放射科, 成都 610041  
夏春潮 四川大学华西医院放射科, 成都 610041  
赵飞 四川大学华西医院放射科, 成都 610041  
李磊 四川大学华西医院放射科, 成都 610041  
张凯 四川大学华西医院放射科, 成都 610041  
李玉明 四川大学华西医院放射科, 成都 610041  
彭婉琳 四川大学华西医院放射科, 成都 610041  
张金戈 四川大学华西医院放射科, 成都 610041  
刘科伶 四川大学华西医院放射科, 成都 610041  
徐旭 四川大学华西医院放射科, 成都 610041  
胡斯娴 四川大学华西医院放射科, 成都 610041  
李真林 四川大学华西医院放射科, 成都 610041 HX_lizhenlin@126.com 
摘要点击次数: 4462
全文下载次数: 1678
中文摘要:
      目的 探讨第2代双源CT大螺距扫描联合智能调制技术及迭代重建技术在急诊主动脉夹层成像中的临床应用价值。方法 连续纳入临床怀疑主动脉夹层成像的急诊患者40例,按随机数表法分为对照组和试验组,每组各20例。对照组行常规扫描,试验组行大螺距联合智能调制技术及迭代重建技术扫描。对主动脉平均CT值、平均噪声、信噪比(SNR)、对比噪声比(CNR)、有效剂量,图像整体质量和主动脉根部图像质量进行评价和分析。结果 40例患者均成功完成CT主动脉夹层成像。对照组与试验组的图像整体质量无差异(P>0.05);但试验组主动脉根部图像质量比对照组好,差异有统计学意义(χ2=22.556,P<0.05)。对照组主动脉平均CT值、平均噪声略高于试验组,但试验组的SNR、CNR高于对照组,差异有统计学意义(t=-21.042、-15.924、8.530、11.495,P<0.05)。对照组有效剂量(10.59±3.89)mSv明显高于试验组的(6.39±0.81)mSv,差异有统计学意义(t=-12.327,P<0.05)。结论 双源CT大螺距扫描联合智能调制技术及迭代重建技术能保证图像整体质量,降低有效剂量,可作为急诊CT主动脉夹层的对照成像方法。
英文摘要:
      Objective To explore the clinical application value of second-generation dual-source CT combined with intelligent modulation and iterative reconstruction in emergency aortic dissection imaging.Methods A total of 40 emergency patients with clinical suspected aortic dissection were included in this study. Conventional scanning was performed in the control group, and large-pitch intelligent modulation and iterative reconstruction were performed in the test group. The mean CT value, mean noise, signal noise ratio(SNR), contrast noise ratio(CNR), effective dose, image quality and aortic root image quality were evaluated and analyzed.Results Totally 40 patients successfully completed CT aortic dissection imaging. There was no difference in image quality between the two groups(P>0.05). The quality of aortic root images in the test group was better than that in the control group, and the difference was statistically significant(χ2=22.556, P<0.05). The mean CT value and mean noise of aorta in the control group were slightly higher than those in the test group. However, SNR and CNR in the test group were higher than those in the control group, and the difference was statistically significant(t=-21.042, -15.924,8.530,11.495, P<0.05). The effective dose of the control group[(10.59±3.89)mSv] was significantly higher than that[(6.39±0.81)mSv] of the test group, the difference was statistically significant(t=-12.327,P<0.05).Conclusions The combined intelligent modulation technique and iterative reconstruction technique with dual-source CT large pitch scanning can meet the requirements of image quality and reduce the effective dose, and can be used as a conventional imaging method for emergency CT of aortic dissection.