黄卓,范瑶华,李文炎,等.直读式剂量计用于介入职业人员眼晶状体剂量实时监测方法的研究[J].中华放射医学与防护杂志,2016,36(12):929-934.Huang Zhuo,Fan Yaohua,Li Wenyan,et al.Study of real-time measurements of occupational staff's eye lens doses by direct-reading dosimeters in interventional procedures[J].Chin J Radiol Med Prot,2016,36(12):929-934
直读式剂量计用于介入职业人员眼晶状体剂量实时监测方法的研究
Study of real-time measurements of occupational staff's eye lens doses by direct-reading dosimeters in interventional procedures
投稿时间:2016-08-19  
DOI:10.3760/cma.j.issn.0254-5098.2016.12.011
中文关键词:  介入职业人员  眼晶状体  个人剂量当量Hp(3)  直读式剂量计  热释光剂量计
英文关键词:Interventional staff  Personal dose equivalent Hp(3)  Eye lens  Direct-reading dosimeters  Thermoluminescence dosimeter (TLD)
基金项目:国家科技支撑计划项目(2014BAI12B04)
作者单位E-mail
黄卓 100088 北京, 中国疾病预防控制中心辐射防护与核安全医学所 辐射防护与核应急中国疾病预防控制中心重点实验室  
范瑶华 100088 北京, 中国疾病预防控制中心辐射防护与核安全医学所 辐射防护与核应急中国疾病预防控制中心重点实验室 fyaohua1@163.com 
李文炎 100088 北京, 中国疾病预防控制中心辐射防护与核安全医学所 辐射防护与核应急中国疾病预防控制中心重点实验室  
欧向明 100088 北京, 中国疾病预防控制中心辐射防护与核安全医学所 辐射防护与核应急中国疾病预防控制中心重点实验室  
岳保荣 100088 北京, 中国疾病预防控制中心辐射防护与核安全医学所 辐射防护与核应急中国疾病预防控制中心重点实验室  
徐辉 100088 北京, 中国疾病预防控制中心辐射防护与核安全医学所 辐射防护与核应急中国疾病预防控制中心重点实验室  
摘要点击次数: 4710
全文下载次数: 2178
中文摘要:
      目的 探索直读式剂量计测量介入职业人员眼晶状体剂量的方法,实现介入职业人员眼晶状体实时剂量的监测和高剂量率报警,为介入职业人员眼晶状体剂量监控和放射防护的改进提供科学依据。方法 选用直读式电子剂量计,以眼晶状体个人剂量当量Hp(3)对其刻度。选择包括单X射线管和双X射线管在内的5台数字减影血管造影(DSA)设备,对心脑血管介入手术中5种介入手术类型的介入人员眼晶状体剂量进行实时测读。对直读式剂量计测读结果进行统计分析,并与同种手术类型的热释光剂量计(TLD)测读结果进行比较。结果 经眼晶状体Hp(3)刻度,直读式剂量计线性拟合度较好,且变异系数<5%。测量冠状动脉造影和脑部支架植入术第一术者眼晶状体Hp(3)平均值,直读式剂量计测得值分别为12.0和24.5 μSv,TLD测得值分别为11.9和22.7 μSv。直读式剂量计与TLD测得剂量趋势吻合。直读式剂量计可获得单例手术中介入职业人员眼晶状体受照剂量,并对其眼晶状体剂量率进行实时监测。结论 直读式剂量计测量眼晶状体剂量的刻度方法可行,测读结果可用于介入职业人员眼晶状体剂量实时监测。
英文摘要:
      Objective To establish the methods for measuring the dose to occupational staff's eye lens in interventional procedures with direct-reading dosimeters, and to realize the real-time monitoring of eye lens dose and warning for high dose rate, thus providing the scientific basis of the staff radiological protection in interventional procedures. Methods Direct-reading dosimeters were calibrated with personal dose equivalent Hp(3). The eye lens doses for occupational staff in different kinds of interventional procedures were measured by the devices with both single- and double X-ray tubes. The data obtained from the direct-reading dosimeters was compared to those obtained from TLDs. Results Direct-reading dosimeters showed good linear fitting with the calibration of Hp(3), and the coefficients of variation were lower than 5%. The average eye lens Hp(3) for the main operator in coronary arteriography and stent implantation in brain obtained by direct-reading dosimeters were 12.0 and 24.5 μSv, respectively, whereas those obtained by TLDs were 11.9 and 22.7 μSv, respectively. The direct-reading dosimeters gave similar trends as TLDs do so. The direct-reading dosimeters were able to provide eye lens Hp(3) in each individual interventional procedure, and to monitor the real-time dose rate as well. Conclusions The calibration of Hp(3) and the data gained by direct-reading dosimeters are reliable. Therefore, the methods for real-time measurement of eye lens dose for occupational staff in interventional procedures are successfully established.