郭延娈,李建彬,王玮,等.基于4D-CT的最大密度投影图像与基于PET-CT不同SUV值勾画的胸段食管癌原发肿瘤IGTV比较研究[J].中华放射医学与防护杂志,2014,34(9):683-687.,et al.Comparison of internal gross target volumes delineated on the maximum intensity projection of four-dimensional CT images and positron emission tomography-CT for primary thoracic esophageal cancer[J].Chin J Radiol Med Prot,2014,34(9):683-687 |
基于4D-CT的最大密度投影图像与基于PET-CT不同SUV值勾画的胸段食管癌原发肿瘤IGTV比较研究 |
Comparison of internal gross target volumes delineated on the maximum intensity projection of four-dimensional CT images and positron emission tomography-CT for primary thoracic esophageal cancer |
投稿时间:2013-12-20 |
DOI:10.3760/cma.j.issn.0254-5098.2014.09.010 |
中文关键词: 胸段食管癌 18F-FDG PET-CT 4D-CT 标准摄取值 内大体肿瘤体积 |
英文关键词:Thoracic esophageal cancer 18F-FDG PET-CT Four-dimensional computed tomography Standardized uptake value Internal gross target volume |
基金项目: |
|
摘要点击次数: 4171 |
全文下载次数: 3133 |
中文摘要: |
目的 比较基于4D-CT的最大密度投影(MIP)图像与基于18F-FDG PET-CT不同SUV值勾画的胸段食管癌原发肿瘤靶区间的体积大小、适形指数(CI)和包含度(DI)。方法 15例胸段食管癌患者序贯完成3D-CT、4D-CT、18F-FDG PET-CT 胸部定位扫描。在4D-CT的MIP图像上勾画食管原发肿瘤的内大体肿瘤体积IGTVMIP,在PET-CT的PET图像上分别选择不同SUV阈值(≥2.0、2.5、3.0、3.5)、最大SUV值 (SUVmax) 的不同百分比(≥20%、25%、30%、35%、40%)及人工视觉观察勾画食管原发肿瘤靶区。结果 IGTVPET2.5、IGTVPET20%、IGTVPETMAN与IGTVMIP体积比值最接近于1,分别为0.86、0.88、1.06;IGTVPET2.0、IGTVPET2.5、IGTVPET20%、IGTVPET25%、IGTVPETMAN与IGTVMIP间CI分别为0.55、0.56、0.56、0.54、0.55,均明显大于其他IGTVPET与IGTVMIP间的CI 值(Z=-3.408~2.215,P<0.05)。IGTVPET2.5、IGTVPET20%、IGTVPETMAN与IGTVMIP 相互间DI值分别为0.77、0.82、0.71和0.67、 0.68、0.82,差异均不明显(P >0.05)。结论 基于PET图像SUV阈值2.5、最大SUV值的20%及人工视觉观察3种方法与基于4D-CT的MIP图像所勾画胸段食管癌原发肿瘤靶区体积大小最接近且空间错位相对较小。 |
英文摘要: |
Objective To compare volumetric size, conformity index (CI), degree of inclusion (DI) of internal gross target volumes (IGTV) delineated on 4D-CT-MIP and PET-CT images for primary thoracic esophageal cancer. Methods Fifteen patients with thoracic esophageal cancer sequentially underwent enhanced 3D-CT, 4D-CT and PET-CT simulation scans. IGTVMIP was obtained by contouring on 4D-CT maximum intensity projection (MIP). The PET contours were determined with nine different threshold methods (SUV≥ 2.0, 2.5, 3.0, 3.5), the percentages of the SUVmax (≥20%, 25%, 30%, 35%, 40%) and manual contours. The differences in size, conformity index (CI), degree of inclusion (DI) of different volumes were compared.Results The volume ratios (VRs) of IGTVPET2.5 to IGTVMIP, IGTVPET20% to IGTVMIP, IGTVPETMAN to IGTVMIP were 0 .86, 0.88, 1.06, respectively, which approached closest to 1. The CIs of IGTVPET2.0,IGTVPET2.5,IGTVPET20%,IGTVPETMAN and IGTVMIP which were 0.55, 0.56, 0.56, 0.54,0.55, respectively, were significantly larger than other CIs of IGTVPET and IGTVMIP(Z=-3.408-2.215,P<0.05). There were no statistical significance in the DIs of IGTVMIP and IGTVPET2.5,IGTVMIP and IGTVPET20%, IGTVMIP and IGTVPETMAN (0.77,0.82,0.71,0.67, 0.68,0.82,P>0.05). Conclusions The targets delineated based on SUV threshold setting of ≥2.5, 20% of the SUVmax and manual contours on PET images correspond better with the target delineated on maximum intensity projection of 4D-CT images than other SUV thresholding methods. |
HTML 查看全文 查看/发表评论 下载PDF阅读器 |
关闭 |
|
|
|