曹磊,邓君,王成国,等.用于油气田测井的CR39快/热中子个人剂量计的初步设计[J].中华放射医学与防护杂志,2011,31(4):489-492.CAO Lei,DENG Jun,WANG Cheng-guo,et al.Preliminary design of CR39 fast/thermal neutron personal dosimeter used in oil and gas field logging[J].Chin J Radiol Med Prot,2011,31(4):489-492
用于油气田测井的CR39快/热中子个人剂量计的初步设计
Preliminary design of CR39 fast/thermal neutron personal dosimeter used in oil and gas field logging
投稿时间:2010-06-07  
DOI:10.3760/cma.j.issn.0254-5098.2011.04.031
中文关键词:  快/热中子个人剂量计  外赋响应  BN前置径迹转换体
英文关键词:Fast/thermal neutron personal dosimeter  Externally assigned response  BN track pre-adaptor
基金项目:
作者单位
曹磊 100088 北京,中国疾病预防控制中心辐射防护与核安全医学所 
邓君 100088 北京,中国疾病预防控制中心辐射防护与核安全医学所 
王成国 内蒙古自治区疾病预防控制中心 
刘运宏 100088 北京,中国疾病预防控制中心辐射防护与核安全医学所 
郭文 100088 北京,中国疾病预防控制中心辐射防护与核安全医学所 
钱叶侃 100088 北京,中国疾病预防控制中心辐射防护与核安全医学所 
孙全富 100088 北京,中国疾病预防控制中心辐射防护与核安全医学所 
摘要点击次数: 3693
全文下载次数: 2678
中文摘要:
      目的 利用前置反冲层提高CR39(Columbia Resin 39)固体核径迹探测器的外赋响应,并改善CR39能量响应特性,研制适用于油气田测井职业照射现场的被动式快/热中子个人剂量监测装置。方法 采用氮化硼(BN)作为CR39探测器的前置径迹转换体,利用10B(n,α)7Li反应产生的α粒子增加CR39探测器的径迹密度,并采用Monte Carlo模拟和标准源照射实验对新设计的探测器进行验证,研究提高CR39探测器的外赋响应性能。结果 中子注量灵敏度是3.46×10-4 径迹/中子,中子剂量当量灵敏度是(7.57±0.41)×102 径迹·cm2·mSv-1,探测线性范围是0.013~52.8 mSv。理论推导和241Am-Be标准中子源实验结果说明,BN前置层的使用有效提高了CR39探测器的探测效率,拓展了剂量计的能量响应范围,初步实现了对热中子引起剂量贡献的定量测量。结论 高灵敏度CR39快/热中子个人剂量计是一种适用于油气田测井环境、具有发展潜力的新型高灵敏度中子个人剂量计。
英文摘要:
      Objective To increase externally-assigned response, improve energy response of CR39 and develop positive fast/thermal neutron personal dosimeter applicable for occupational exposure in oil and gas field logging by using pre-recoil layer. Methods The externally-assigned response of CR39 detector was improved through increasing the track density by using the α particle induced by the reaction of 10B(n,α)7Li with the BN as pre-recoil layer, and the increase was vilified by using both Monte-Carlo simulation and experiment exposed by standard neutron source. Results Fast/thermal neutron personal dosimeter's neutron flux sensitivity and neutron dose equivalent sensitivity were 3.46×10-4 track per neutron, (7.57±0.41)×102 track·cm2·mSv-1, respectively. The detecting linearity range was between 0.013 and 52.8 mSv. According to theoretical derivation and experiment of standard 241Am-Be neutron source, detecting efficiency and energy response of CR39 were effectively improved, and quantitative measurement of dose contributed by thermal neutron was realized. Conclusions CR39 fast/thermal neutron personal dosimeter of high sensitivity is applicable to oil and gas field logging environment and of potential development.