蒙特卡罗方法计算外照射所致红骨髓剂量方法的研究
Monte Carlo simulation methods of determining red bone marrow dose from external radiation
  
DOI:10.3760/cma.j.issn.0254-5098.2011.02.029
中文关键词:  蒙特卡罗方法  红骨髓  剂量  人体模型模拟计算
英文关键词:Monte Carlo method  Red bone marrow  Dose  Human phantom simulation
基金项目:卫生行业科研专项(200802018)
作者单位
高佚名 200032 上海,复旦大学放射医学研究所 
刘海宽 200032 上海,复旦大学放射医学研究所 
顾乃谷 200032 上海,复旦大学放射医学研究所 
吴锦海 200032 上海,复旦大学放射医学研究所 
黄卫琴 200032 上海,复旦大学放射医学研究所 
王凤仙 200032 上海,复旦大学放射医学研究所 
王力 200032 上海,复旦大学放射医学研究所 
苏旭 中国疾病预防控制中心辐射防护与核安全医学所 
摘要点击次数: 3772
全文下载次数: 2842
中文摘要:
      目的 对现有的红骨髓剂量模拟计算方法进行比较和分析,为确定更为合理的计算方法提供依据。方法 借助MCNPX蒙特卡罗模拟软件,模拟了能量20 keV~10 MeV 的γ光子源,对Rensselaer理工学院(RPI)体素人体模型进行前后(AP)全身均匀照射,分别采用直接能量沉积法、剂量响应函数法(DRF)、King-Spiers因子法和质能吸收系数法(MEAC),进行红骨髓剂量的模拟计算。结果 在入射γ光子能量低于100 keV时,直接能量沉积法的结果最大,而质能吸收系数法和King-Spiers因子法的结果更为合理;在入射γ光子能量高于150 keV时,King-Spiers因子法给出的结果要略高于其他方法的结果,但其能够反映出红骨髓对γ光子能量更强的吸收能力。结论 综合比较低能区和高能区不同方法给出的结果后,发现King-Spiers因子法是最合理的估算红骨髓剂量的方法。
英文摘要:
      Objective To provide evidence for a more reasonable method of determining red bone marrow dose by analyzing and comparing existing simulation methods. Methods By utilizing Monte Carlo simulation software MCNPX, the absorbed doses of red bone marrow of Rensselaer Polytechnic Institute (RPI) adult female voxel phantom were calculated through 4 different methods: direct energy deposition, dose response function (DRF), King-Spiers factor method and mass-energy absorption coefficient (MEAC). The radiation sources were defined as infinite plate sources with the energy ranging from 20 keV to 10 MeV, and 23 sources with different energies were simulated in total. The source was placed right next to the front of the RPI model to achieve a homogeneous anteroposterior radiation scenario. The results of different simulated photon energy sources through different methods were compared. Results When the photon energy was lower than 100 keV, the direct energy deposition method gave the highest result while the MEAC and King-Spiers factor methods showed more reasonable results. When the photon energy was higher than 150 keV taking into account of the higher absorption ability of red bone marrow at higher photon energy, the result of the King-Spiers factor method was larger than those of other methods. Conclusions The King-Spiers factor method might be the most reasonable method to estimate the red bone marrow dose from external radiation.