王月兴,杨翊方,鲁永杰,等.252Cf中子照射中国参考人模体24Na比活度的实验研究[J].中华放射医学与防护杂志,2011,31(1):67-70,78.WANG Yue-xing,YANG Yi-fang,LU Yong-jie,et al.Experimental research on specific activity of 24Na using Chinese reference man phantom irradiated by 252Cf neutrons source[J].Chin J Radiol Med Prot,2011,31(1):67-70,78
252Cf中子照射中国参考人模体24Na比活度的实验研究
Experimental research on specific activity of 24Na using Chinese reference man phantom irradiated by 252Cf neutrons source
投稿时间:2010-01-14  
DOI:10.3760/cma.j.issn.0254-5098.2011.01.020
中文关键词:  中子  252Cf  血液  24Na比活度  中国参考人
英文关键词:Neutron  252Cf  Blood  24Na specific activity  Chinese reference man
基金项目:后勤系统重点科研项目(99-3302)
作者单位
王月兴 200433 上海,海军医学研究所防护医学研究室 
杨翊方 200433 上海,海军医学研究所防护医学研究室 
鲁永杰 200433 上海,海军医学研究所防护医学研究室 
张建国 200433 上海,海军医学研究所防护医学研究室 
邢宏传 200433 上海,92330部队 
摘要点击次数: 3107
全文下载次数: 2269
中文摘要:
      目的 研究裂变中子谱照射中国参考人单位中子注量在血液中产生的24Na比活度AB/Φ,并分析实验场所地板、墙壁和天花板等的散射中子对测量结果的影响。 方法 利用强度约3?108中子/s的252Cf中子源对中国参考人模体进行照射。模体躯干尺寸按中国参考人制作,外壳由4 mm有机玻璃制成,内有人体组织当量液,主要元素的重量比为H ∶N ∶O ∶C=10.6 ∶2.5 ∶63.2 ∶23.7,密度1.007 g/cm3 (20℃)。中子源到模体长轴的照射距离d(m)分别为1.1、2.1、3.1和4.1。 中子源和模体的剑突部位离地面1.6 m。结果 单位中子注量照射在模体内产生的24Na平均比活度与照射距离有关,根据实验结果推导出的AB/Φ的最大值(AB/ΦM)约为1.85?10-7 Bq ?cm2 ?g-1结论 AB/ΦM相当于252Cf中子谱平行射线照射的情况,这一数据比文献报道的BOMAB模体的实验结果大3%。实验表明,在照射场所的地面、墙壁散射中子对24Na比活度有显著的贡献,但对入射中子的剂量贡献却相对较小。因此,在实际的中子照射事故中,利用血液24Na比活度估算受照者的中子剂量时,事故场所散射中子的贡献将导致过高估计中子剂量,需要进行修正。
英文摘要:
      Objective To investigate the specific activity of 24Na per unit neutron fluence,AB/Φ, in blood produced for Chinese reference man irratiaded by 252Cf neutron source, and to analyze the effects of scattering neutrons from ground, wall, and ceiling in irradiation site on it. Methods A 252Cf neutron source of 3?108 n/s and the anthropomorphic phantom were used for experiments. The phantom was made from 4 mm thick of outer covering by perspex and the liquid tissue-equivalent substitute in it. The data of phantom dimensions fit into Chinese reference man. The weight ratios of H,N,O and C in substitute equal to 10.6 ∶2.5 ∶63.2 ∶23.7, and its density was 1.006-1.008 g/cm3 (20℃). The irradiation-distances, d, from source to long axis of phantom were 1.1, 2.1, 3.1 and 4.1 m, respectively. Both the neutron source and the position of xiphisternum of the phantom were 1.6 m above the floor. Results The average specific activity of 24Na per unit neutron fluence was related to the irradiation-distances, d, and its maximum value,AB/ΦM,deduced by experimental data was about 1.85?10-7 Bq ?cm2 ?g-1. Conclusions The AB/ΦM corresponds to that of phantom irradiated by plane-parallel beams, and the value is about more 3% than that by BOMAB phantom reported in literature. It has shown that floor-(wall-)scattered neutrons in irradiation site have significant contribution to the specific activity of 24Na ,but they contributed relatively little to the induced neutron doses. Consequently, using the specific activity of 24Na for assessing accidental neutron doses received by an individual, the contribution of scattered neutrons in accident site will lead dose to be overestimated, and need to be correct.