刘建新,刘剑,窦砚彬,王继琛,孙洪跃.64排螺旋CT冠状动脉成像的前瞻性与回顾性心电门控技术的图像质量及辐射剂量的比较研究[J].中华放射医学与防护杂志,2009,29(3):320-322
64排螺旋CT冠状动脉成像的前瞻性与回顾性心电门控技术的图像质量及辐射剂量的比较研究
Comparative study of image quality and radiation dose between prospective and retrospective ECG gating technique in coronary artery imaging with 64-slice spiral CT
投稿时间:2008-10-27  
DOI:10.3760/cma.j.issn.0254-5098.2009.03.028
中文关键词:  64排螺旋CT  心电门控  冠状动脉  辐射剂量
英文关键词:64-slice spiral CT  ECG gating  Coronary artery  Radiation dose
基金项目:
作者单位
刘建新 100034, 北京大学第一医院医学影像科 
刘剑 100034, 北京大学第一医院医学影像科 
窦砚彬 100034, 北京大学第一医院医学影像科 
王继琛 100034, 北京大学第一医院医学影像科 
孙洪跃 100034, 北京大学第一医院医学影像科 
摘要点击次数: 3078
全文下载次数: 2361
中文摘要:
      目的 研究前瞻性心电门控触发(prospective ECG-triggering)与回顾性心电门控(retrospective ECG gating)两种技术方法行冠状动脉CTA检查时,对冠状动脉图像质量及辐射剂量的比较。方法 33名疑似冠状动脉疾病的患者分两组进行对比研究。前瞻组16例为前瞻性心电门控成像,心率小于65次/min;回顾组17例为回顾性心电门控成像,心率小于75次/min。记录两组的辐射剂量并统计分析,同时进行图像质量评价。结果 两组图像质量比较,差异无统计学意义(P>0.05)。前瞻性心电门控冠状动脉CTA的平均DLP 234.4mGy·cm,占回顾性心电门控冠状动脉CTA的平均DLP974.4mGy·cm的24.1%。前瞻性心电门控冠状动脉CTA的患者的平均有效剂量为3.2mSv,回顾心电门控冠状动脉CTA患者的为13.6mSv,降低76.47%。结论 64排螺旋CT在前瞻性心电门控冠状动脉CTA与回顾性心电门控冠状动脉CTA比较可以获得相似的图像质量,可大幅降低患者的有效剂量对于不能接受高辐射剂量且心率较低的受检人群具有重要的临床价值。
英文摘要:
      Objective To compare the image quality and radiation dose between prospective ECG-trigering and retrospective ECG gating technique in coronary artery imaging. Methods 33 patients suspected coronary artery disease were included in this study and divided into experimental group (prospective ECG-triggering coronary artery imaging, heart rate <65bpm, 16 patients)and control group (retrospective ECG gating coronary artery imaging, heart rate<75bpm, 17 patients). Radiation dose was recorded for statistical analysis. At the same time, image quality was evaluated. Results There were no significant differences in image quality between two groups (P>0.05). The mean DLP of experimental group (234.4 mGy·cm) was DLP of control group (974.4mGy·cm) 24.1%. The mean effective dose of prospective ECG gating coronary artery imaging was 3.2 mSv. Effective dose reduced 76.47%. Conclusions Prospective ECG gating coronary artery imaging can obtain the similar image quality compared with prospective ECG gating coronary artery imaging but the effective dose reduced 76.47%. Prospective ECG gating coronary artery imaging has clinical value to peoples who are able to not accept high radiation dose and with low heart rate.