周志国,张萍,高献书,等.食管癌连续7天常规分割加速放射治疗的远期疗效分析[J].中华放射医学与防护杂志,2007,27(6):549-551.ZHOU Zhi-guo,ZHANG Ping,et al.The long effect of 7-day continuous accelerated irradiation in patients with esophageal carcinoma[J].Chin J Radiol Med Prot,2007,27(6):549-551
食管癌连续7天常规分割加速放射治疗的远期疗效分析
The long effect of 7-day continuous accelerated irradiation in patients with esophageal carcinoma
投稿时间:2006-11-27  
DOI:
中文关键词:  食管癌  放射治疗  加速分割  生存率  总治疗时间
英文关键词:Esophageal cancer  Radiotherapy  Accelerated fractionation  Survival rate  Overall treatment time
基金项目:
作者单位E-mail
周志国 050011, 河北医科大学第四医院  
张萍 050011, 河北医科大学第四医院  
高献书 050011, 河北医科大学第四医院 gaoxs@heinfo.net 
乔学英 050011, 河北医科大学第四医院  
王薇 050011, 河北医科大学第四医院  
万钧 050011, 河北医科大学第四医院  
摘要点击次数: 3456
全文下载次数: 1891
中文摘要:
      目的 连续7 d常规分割加速放射治疗方案和后程加速超分割放射治疗方案治疗食管癌的疗效比较。方法 57例食管鳞癌患者随机分为两组,连续7 d常规分割加速放射治疗组(连续组)29例和后程加速超分割放射治疗组(后超组)28例。连续组治疗方法1次/d,2 Gy/次,7 d/周,吸收剂量60 Gy,30次,30 d;后超组前半程为常规分割(5次/周,2 Gy/次),照射至30 Gy时改加速超分割(2次/d,1.5 Gy/次,5 d/周),吸收剂量60 Gy,共35次,33~35 d。结果 连续组和后超组1年、2年、3年总生存率分别为62.07%、37.93%、25.60%和64.29%、35.71%、25.00%。1年、2年、3年局部控制率连续组和后超组分别为82.93%、70.59%、52.94%和70.38%、45.95%、40.84%,3年疾病特异性生存率连续组为28.72%,后超组为25.00%。两组间晚期反应差异未见统计学意义。结论 连续组3年生存率与后超组相当,局部复发、未控和转移仍是食管癌放射治疗失败的主要原因。
英文摘要:
      Objective The curative effect of 7-day continuous accelerated irradiation schedule (CAIR) was compared with late course accelerated hyper-fractionation radiotherapy schedule (LCAF) for esophageal carcinoma in a randomized trial. Methods Fifty-seven patients with squamous cell carcinoma of esophagus were randomly divided into two groups, 29 to the CAIR group and 28 to the LCAF group. In CAIR group dose per fraction of 2.0 Gy was given once per day at 24 h intervals and the overall treatment time was 4.2 weeks (30 days). The patients in the LCAF group received conventional fractionation radiotherapy, 2 Gy/fraction, to a dose of 30 Gy in 15 fractions during 3 weeks, followed by accelerated fractionation radiotherapy, 2 fractions per day at 1.5 Gy/fraction (with a minimal interval of 6 h between fractions), and the overall treatment time was 5 weeks. The total dose was 60 Gy in both groups. Results The 1,2 and 3-year overall survival rate were 62.07%, 37.93% and 25.60% in CAIR group and 64.29%, 35.71% and 25.00% in LCAF group. The 3-year local control rate was 52.94% and 40.84% in CAIR and LCAF groups, respectively. The 3-year cause-specific survival rate was 28.72% in CAIR and 25.00% in LCAF group. There was no significant difference of late effect in two groups.Conclusions The 3-year survival rate and local control rate were similar in two groups. The local relapse and metastasis were the main reason of failure to radiotherapy to esophageal carcinoma.
HTML  查看全文  查看/发表评论  下载PDF阅读器
关闭