孙连陞,赵淑权,C. B. Meinhold.有效剂量与有效剂量当量的异同[J].中华放射医学与防护杂志,1995,15(4):234-236
有效剂量与有效剂量当量的异同
Comparison of effective dose and effective dose equivalent
投稿时间:1994-11-17  修订日期:1995-02-25
DOI:
中文关键词:  有效剂量  有效剂量当量
英文关键词:Effective dose  effective dose equivalent  equivalent dose  and dose equivalent
基金项目:
作者单位
孙连陞 11973 美国纽约长岛布鲁海文国家实验室 
赵淑权 上海放射医学研究所 
C. B. Meinhold 11973 美国纽约长岛布鲁海文国家实验室 
摘要点击次数: 2919
全文下载次数: 1617
中文摘要:
      本文作者主要讨论ICRP60号出版物中提出的有效剂量,与ICRP26号出版物中的有效剂量当量,在概念和使用上比较它们的异同。
英文摘要:
      The ICRP publication 60, 1990 radiological protection recommendations, including the quantities and units, were designed to supersede all their former similar recommendations. However, there are difficulties in application because the ICRP Publication 26 recommendations are currently in use in the United States and many countries as protection standards for radiation users and because the new quantity effective dose is different from the quantity effective dose equivalent given in ICRP Publication 26. This paper discusses this difference and concludes that mixing ICRP Publication 60 and ICRP Publication 26 dosimetry systems could be misleading, so it must be used with great care according to its specifications.